5.3 Flushing and Bleeding the Filter Cartridge
Note:
A bucket with a minimum capacity of 10L is needed for fl ushing/bleeding.

Place the bucket under the fl ush hose and open the fl ush valve

16

.

Open the inlet valve

6

on inlet hose

5

while holding the fl ush hose

in the bucket. Flush with at least 10 litres.
Close the fl ush valve

16

and empty the bucket.

Check system for any leaks.
Note installation date of the fi lter system on pressure vessel

1

and

next exchange date on the enclosed sticker (PURITY 1200 Clean:
light blue sticker, PURITY 1200 Clean Extra: red sticker) and attach it
to the Service Pass on the pressure vessel

1

.

6 Exchanging the Filter Cartridge

The fi lter cartridge must be replaced after 6–12 months, at the latest 12 months after
commissioning, irrespective of the level of exhaustion of the fi lter system. If the capacity
of the fi lter cartridge has been exhausted (Chapter 7), it must be replaced earlier.

!

Caution: During the exchange, carefully examine all dismantled parts! Faulty parts

must be exchanged, dirty parts cleaned! Read the operating and safety information
(Chapter 3) prior to replacement. After the product has been stored at temperatures
below 0°C, it must be stored with the original packaging open at the ambient temperature
of the place of installation for at least 24 hours before entering use.





17

Advertising