9 troubleshooting – Brita 1200 User Manual

Page 12

Advertising
background image

Regularly clean the outside of the fi lter system with a soft, damp cloth.

!

Caution: Do not use any substances incompatible with the material (Chapter 3.4) or

astringent, abrasive cleaning agents.

9 Troubleshooting

9.1 No water fl ow
Cause:

Water intake closed.

Troubleshooting: Open water intake on the upstream stop valve or inlet valve

6

on inlet

hose

5

.

!

Caution: The following faults may be remedied only by trained and authorised

personnel.

9.2 No or low water fl ow in spite of open water intake
Cause:

Mains pressure too low.

Troubleshooting: Check mains pressure.

If the fault continues to occur in spite of adequate mains pressure,
check the fi lter system and fi lter cartridge and change if necessary.

!

Caution: Prior to exchange read the technical data (Chapter 10) and

the operating and safety information (Chapter 3).

9.3 Leaking screw connections
Cause:

Screwed connections not fi tted correctly.

Troubleshooting:

Check mains pressure. Check all screwed connections and mount
according to Chapter 4.
If the fault continues, exchange fi lter system.

!

Caution: Prior to exchange read the technical data (Chapter 10) and

the operating and safety information (Chapter 3).

9.4 Leak continues after fi lter has been replaced
Cause:

O-ring on fi lter cartridge not sitting correctly.

Troubleshooting:

Check correct seat of the O-ring (Chapter 6.2).

!

Caution: Prior to dismantling read the data (Chapter 10) and the

operating and safety information (Chapter 3).

20

Advertising