13 Technical specifications

Display range
Display

4-digit 7-segment LED display, red, height of digits 14.2 mm
3 LED for active sensor
4 LED for switching relays

Display range

- 999..9999 (adjustable by user)

Display units with background lighting

bar, kg/cm², MPa, psi, °C, °F, l/min, mA, V, Hz, kN, m, mm, l, gal,
gal/min, 1/min, and more

Input data
Analogue signal input(s)
Measuring range(s) (up to 3 analogue inputs) adjustable: 4..20 mA, 0..5 V or 0..10 V
Accuracy class

± 0.5 % at 25 °C

Pt 100 input
Measuring range

- 25..100 °C

Accuracy class

± 0.5 % at 25 °C

Frequency / counter input
Signal threshold

0..0.6 V = LOW
3..24 V = HIGH

Frequency range

15 Hz .. 4 kHz

Output data
Analogue output

adjustable: 4..20 mA, Ohmic resistance 400 N or

0..10 V, Ohmic resistance 2 kN

Accuracy of the analogue output

± 0.5 % at 25 °C

Rise time

70 ms

Switching outputs
Type

2 or 4 relays each with separate common supply

Switching voltage

0.1..250 VAC

Switching current

9 mA .. 2 A

Switching capacity

400 VA, 50 W (for inductive loads, use varistors)

Life expectancy of the switching contacts

20 million at minimum load
1 million at nominal load

Reaction time (with switching delay = 0 ms)

approximately 20 ms

Setting range of the switching points

1.5..100 % of the pre-set display range

Setting range of the switching hystereses
(switch-back points)

0.5..99 % of the pre-set display range

Interface

Serial interface RS232
Baud rate 19,200 bauds – 8 data bits – 1 start and stop bit –
no parity – no handshake

Ambient conditions
Nominal temperature range

0 .. + 50 °C

Operating temperature range

0 .. + 50 °C

Storage temperature range

- 40 .. + 80 °C

- mark

DIN EN 61000-6-1 / 2 / 3 / 4

Other data
Housing

Control panel housing 96 x 48 x 109 mm
Control panel cut-out 92 (+0.8) x 45 (+0.6) mm
Front panel thickness 1.25.. 5 mm
Maximum installation depth 121 mm

Electrical connections

Supply voltage: plug-in terminal block, 2 pole, RM 5.08
Inputs / outputs: plug-in terminal block, 11 pole, RM 3.5
Relays: plug-in terminal block 6 pole, RM 5.08
Max. cross section of the connections 1.5 mm² for inputs / outputs
Max. cross section of the connections 2.5 mm² for supply voltage and
relays

Supply voltage

85..265 VAC 50 / 60 Hz or
12..32 VDC

Power consumption

15 VA at 85..230 VAC, fuse protection 1 A inert

Supply of the measurement transmitter

12

±

1 % VDC max. 20 mA per analogue input

Protection class to DIN 40050

IP 20

Reverse polarity protection of the supply
voltage, excess voltage, override protection

provided

Weight

approximately 320 g