7.2 Overview of basic settings menu

Menu point

Setting

Setting range

Default setting

Allocation of switching output 1 to sensor (S.S.1)

Switching output 1 allocated to sensor 1

Switching output 1 allocated to sensor 2

(Pt 100 sensor)

SEn.1
SEn.2

SEn.1

Switching function switching output 1 (S.M.1)

Switching output 1 set to switch point and

hysteresis mode

Switching output 1 set to switching window

SP
Win

SP

Switching direction switching output 1 (S.d.1)

Relay activated

R

elay deactivated

on
oFF

on

Switch-on delay switching output 1 (T.on1)

Time, in seconds, which must elapse once the particular switch
point has been reached or exceeded in order for a switching
function to occur.

0..99.99

0

Switch-off delay switching output 1 (T.oF1)

Time, in seconds, which must elapse once the value has fallen
below the particular switch-back point in order for a switching
function to occur.

0..99.99

0

Allocation of switching output 2 to sensor (S.S.2)

Similar to switching output 1 (see above), and likewise for:

Switching function (S.M.1)

Switching direction (S.d.2)

Switch-on delay (T.on.2)

Switch-off delay (T.oF.2)

SEn.1
SEn.2

SEn.1

Allocation of switching output 3 to sensor (S.S.3)

Similar to switching output 1 (see above), and likewise for:

Switching function (S.M.3)

Switching direction (S.d.3)

Switch-on delay (T.on.3)

Switch-off delay (T.oF.3)

SEn.1
SEn.2

SEn.1

Allocation of switching output 4 to sensor (S.S.4)

Similar to switching output 4 (see above), and likewise for:

Switching function (S.M.4)

Switching direction (S.d.4)

Switch-on delay (T.on.4)

Switch-off delay (T.oF.4)

SEn.1
SEn.2

SEn.1