INCRA Mast-R-Lift II User Manual

Page 6

Advertising
background image












































1. Turn the Lift upside down on a table with

the threaded height adjustment rod
facing you.


2. Remove the ¼-20 x 1” Cap Screws

from the Carriage Nut Cover (Figure 11)
and remove the cover and o-ring
(Figure 12)

Figure 12

Figure 14

5.

Slide the carriage back up ensuring the
dowel pin in the carriage aligns with the
slot in the carriage nut. (Figure 15)

Figure 11

3. Slide the carriage all the way up

towards the top plate of your Mast-R-
Lift™ II

Figure 13

4. Turn the carriage nut clockwise

ensuring when you complete your
adjustment that the slot in the carriage
nut aligns with one of the slots on the
anitbacklash nut. (Figure 14)

To lock
your lift
turn lift
handle
clockwise
to the
“LOCKED”
position

To unlock
your lift turn
lift handle
counter-
clockwise to
the
“UNLOCKED”
position

RE-ADJUSTING THE THREAD TENSION

All JessEm Lifts feature our patented thread
tensioning design. Thread tension is set at the
factory and depending on the amount of use you
may have to reset this adjustment periodically,
depending on the amount of tension you desire.

If the bit height ever begins to change (or drop)
during use, the thread tensioning likely needs to be
reset.

Advertising