MDC-360 DEPOSITION CONTROLLER

action indefinitely. So the set hold in state action will cause the controller to hold
in the current state until the clear hold in state action is received and the exit state
condition is meet.

Format: Header, Address=1, Instruction=38, Length=1, Action Code (0-
8), Checksum

Example: To initiate a terminate deposit action the computer would send:

Chr$(255)+Chr$(254)+Chr$(1)+Chr$(38)+Chr$(1)+Chr$(6)+Chr$(210)

40. Send run-time values (Code #39)

Instructs the controller to send one run-time value base on the value# received.

Format: Header, Address, Instruction=39, Length=1, value #(0-12) 1byte,
Checksum.

A description of the run-time value list is as follows:

Value#

Value Name

Length (bytes)

Format

Units

0 Power

4

String

%

1 Thickness

5 String

2 Deposition

rate

4

String

Å/sec

3

Time to go

7

String

Seconds

4 Crystal

health

2 String

%

5 Layer

number

3 String

None

6 Rate

deviation

4 String

%

7

Active process number

1

BCD (0-98)

8

Active material number

1

BCD (0-31)

9

Active sensor number

1

BCD (1-4)

10

Active crystal number

1

BCD (1-8)

11

Active source number

1

BCD (1-4)

12

Active pocket number

1

BCD (1-8)

13

Sensor #1 Health

1

BCD (0-99,

255=Failed)

14

Sensor #2 Health

1

BCD (0-99,

255=Failed)

15

Sensor #3 Health

1

BCD (0-99,

255=Failed)

16

Sensor #4 Health

1

BCD (0-99,

255=Failed)

The string values are in ASCII format including decimal points or colons.

Example: To instruct the controller to send the layer number value, the computer
would send:

Chr$(255)+Chr$(254)+Chr$(1)+Chr$(39)+Chr$(1)+Chr$(5)+Chr$(210)

The 360 will return the layer number as a three byte string.

41. Enable/Disable the front panel keyboard (Code #40)

COMPUTER INTERFACE

11-24