Quick programming reference – Johnson Systems DPC-24-3000 Series Digital Pack Controller User Manual

Page 11

Advertising
background image

www.johnsonsystems.com

11

Quick Programming Reference

to System Configuration Menu Items

Basic Menus
1. ADDRESS

Set the DMX start address.

2. DMXA-TRM

Enable or disable termination on the DMX-A input.

3. DMXB-TRM

Enable or disable termination on the DMX-B input.

Advanced Menus
4. SCENESET

Enable and setup 12 or 24 different backup scenes.

5. FADETIME

Set the fade time for each of the 12 or 24 scenes from 0 to 99 seconds.

6. SNAPSHOT

Record DMX levels into the backup scenes.

7. DIM TEST

Test the dimmer outputs one at a time, or all at once.

8. MONITOR

View the control level to each dimmer output.

9. DMX MODE

Configure the mode of the on-board DMX protocol manager.

10. 2 RM SET

Set the two room assignment for each of the dimmer outputs.

11. SH TIME

Set the DMX status hold time from 0 to 99 minutes or infinite.

12. DC PATCH

Configure the dimmer to channel patch for the dimmer pack.

13. DIM CURV

Configure the dimmer curve for each output.

14. VOUT LIM

Set the maximum RMS output voltage for each dimmer.

15. REGULATE

Enable or disable the dimmer output voltage regulation.

16. STANDBY

Enable or disable the power savings standby mode.

17. TEST INC

Set the test increment units to percent or hexadecimal.

18. L-BUTTON

Set the mode of the 12 or 24 local buttons to scene, bump or disabled.

19. Ø-PATCH

Set the zero-cross phase reference for each dimmer control output circuit.

20. V-RANGE

Set the supply voltage range for 120 Volts or 240 Volts operation.

21. LINE V

View the RMS line voltage for each power phase.

22. LINE F

View the line frequency of phase A.

23. CTL TEMP

View the temperature of the microcontroller.

24. RTIME

View the total run time of the microcontroller.

25. HARD-KEY

View the microcontroller’s unique six-character hard-key code.

26. SERIAL#

View the microcontroller’s unique six-character silicone serial number.

27. VERSION

View the microcontroller’s firmware version.

28. EEPROM

View the type of EEPROM memory module plugged in.

29. FW-LOAD

Load new firmware into the microcontroller via the EEPROM memory module.

30. RESTORE

Restore parameters saved in the EEPROM memory module.

31. BACKUP

Backup parameters and save them in the EEPROM memory module.

32. PRINTOUT

Print various system configuration settings using a hand held infrared printer.

33. DEFAULTS

Set various system configuration settings to the factory default.

34. LED INT

Set the LED intensity for the programming switches.

35. LCD VIEW

Adjust the contrast of the LCD Display for optimum viewing.

Advertising
This manual is related to the following products: