Johnson Systems DPC-24-3000 Series Digital Pack Controller User Manual

Page 13

Advertising
background image

www.johnsonsystems.com

13

Advanced Menus

4. SCENESET

Enable and setup 12 or 24 different backup scenes.

When scene mode (SCENESET) is activated the selected scene will be held with

no timeout until the menu is exited. The 12 or 24 local buttons (L-BUTTON) are

automatically set for SCENE mode and can be used to activate scenes. The 12 or 24

control channel levels are configured within the menu and can be modified on the fly.

Scene mode is useful when an external controller is not available and independent

internal control is required.

Press EXECUTE to enter the menu and activate scene mode.

SCENE>01

Displays the scene (01) to be activated.

SCENE>24

Press MENU ( ) to select a different scene from 01 to 12 or 24.

CTRL: ON

Control (CTRL) is ON via the selected scene.

CTRL:DMX

Control (CTRL) is via DMX and takes priority over scene mode.

CTRL:HLD

Control (CTRL) is via DMX status hold (HLD) and takes priority over scene mode.

CTRL:INF

Control (CTRL) is via DMX status hold (INF) and takes priority over scene mode.

SCENE>24

Press EXECUTE to activate the selected scene.

SCENE:24

The colon (:) flashes twice per second while fading to the selected scene.

SCENE:24

The colon (:) stops flashing when fade is complete and the selected scene is active.

SCENE>24

Press MENU ( ) to select a different scene from 01 to 12 or 24.

SCENE 24

Press EXECUTE to modify the selected scene.

C>01L 00

The second line on the LCD indicates the control channel (C) and level (L).

C>24L 00

Press MENU ( ) to select the control channel (C) to modify from 01 to 12 or 24.

C 24L>00

Press EXECUTE to toggle from channel (C>) to level (L>) selection.

C>24L 00

Press ESCAPE to toggle from level (L>) to channel (C>) selection.

C 24L>FL

Press MENU ( ) to select the output level (L) for the selected channel from 00 to FL.

CLEAR???

Press EXECUTE to clear the selected preset, and set all channels to 00 level.

SURE ???

Press EXECUTE if you are sure to clear the selected preset.

DONE !!!

Indicates the selected preset has been cleared.

WAIT...

Press ESCAPE to exit and the menu and save programmed scene levels.

Press ESCAPE to back-up within the menu, or exit/deactivate scene mode.

Press RESET to exit scene mode without saving programmed scene levels.

NOTE: When scene mode is activated, DMX and DMX status hold (SH-TIME)

automatically takes precedence over scene mode. Scene mode will only

activate dimmers assigned to room “A”.

5. FADETIME

Set the fade time for each of the 12 or 24 scenes from 0 to 99 seconds.

The factory default is 5 seconds for all 12 or 24 scenes.

Press EXECUTE to enter the menu.

S>01T 05

Displays the scene (S>01) and assigned fade time (T 05).

S>24T 05

Press MENU ( ) to select a different scene from 01 to 12 or 24.

S 24T>05

Press EXECUTE to toggle between scene (S>) and fade time (T>) selection.

S 24T>99

Press MENU ( ) to select a different fade time from 00 to 99 seconds.

Press ESCAPE to exit the menu and save the selected fade time.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 2 minutes of inactivity and save.

Advertising
This manual is related to the following products: