Exos system diagram, Led display panel – Koolance EX2-755-R User Manual

Page 5

Advertising
background image

2

3

User Manual

Exos System Diagram

Reservoir & Pump

Radiator Cooling Fans

(quantity depends on model)

Coolant Inlet

Power Connection

LED Display Panel

Coolant Outlet

Current Mode

Value

Mode Select

Display in ºC or ºF

Decrease Setting

Increase Setting

System Features

CAUTION: Due to electrical tolerances, the lowest pump speed set-
tings may stop the pump from running. Be sure the pump continues
to run when operated at lower speeds.

!

Radiator - The primary heat exchanger is the main cooling element, and provides

high thermal dissipation in a relatively small area. Inside, a metal web of louver
fins stretch between flat liquid pipes.

Reservoir & Pump - The coolant tank is transparent for easy liquid-level monitoring

through the top window. It is filled through a small metal fill port on top. The reservoir
is illuminated for easy observation.

LED Display Panel

CAUTION: This cooling system allows full user control of hardware

safety settings, such as audio alarm, shutdown, and pump speed.

Please be sure to configure your LED Display Panel properly, or dam-

age to your computer, data, and/or equipment could result.

!

Modes

There are seven display options. All are reached by continually pressing the SET
(mode select) button:

1. Temperature sensor #1 is displayed
2. Temperature sensor #2 is displayed
3. Temperature sensor #3 is displayed
4. All temperature sensors are cycled automatically
5. Fan setting is displayed (mode “F” is shown)
6. Pump setting is displayed (mode “P” is shown)
7. All temperatures, fan, and pump settings are cycled automatically

Temperature Sensors

This cooling

system can monitor up to 3 included temperature sensors. The first

LED digit indicates which sensor channel is currently displayed in the temperature
reading. To cycle through sensors, press SET.

Fan Speed

This option adjusts the radiator fan speed. Higher speeds can improve performance,
but will produce more noise. There is 1 automatic and 10 manual fan settings (1-
10). From the fan (“F”) or any cycle mode, press the

▼ or ▲ buttons to adjust fan

settings, or hold down an arrow to skip to the lowest or highest mode directly.

Automatic mode will adjust the fans for you based on temperature values from
sensor #1. This mode is reached by lowering the fan setting to “0” (Aut / A will
be displayed).

Pump Speed

There are 10 manual pump settings (1-10). From the pump (“P”) mode, press

Relay Switch

Advertising