External Nozzles & Power Cable

Cut tubing into two segments. You
will need to connect each to the rear
nozzles.

Each hose connection will use a threaded compression
ring or hose clamp to keep it secure. Be sure to thread
the compression ring or hose clamp onto the hose
before attaching it.

Once the hoses are connected, plug the
external power cable into the cooling
system.

Squeeze the tube while pushing it firmly
over the nozzle. Tubing should completely
cover the nozzle.

Tighten the connection by sliding the
compression fitting down over the nozzle and
screwing securely. For hose barbs, use pliers
to move it into the proper position.

Install the nozzles you purchased for your cooling
system. It’s recommended to hand-tighten all
fittings to avoid damaging the cooling unit.

Connecting the Slot Adapter

The included Slot Adapter allows the cooling system to connect with ATX computers
through an available card slot. It is responsible for inlet/outlet tubes, the external
power cable, temperature sensors, and shutdown lead.

There are 5 main internal connections to the Slot Interface card which will be made.
The cooling system can appear to operate without some of these connections, but
hardware safety features or temperature monitoring on affected channels will be
disabled.

Start by connecting Temperature Sensors #1, #2, and #3. Then connect the ATX
Pass-Through wire.

ATX Power

Switch

Pass-Through

Temperature

Sensor #1

Temperature

Sensor #2

Temperature

Sensor #3

Optional Fan

Headers

Main 12V Power

Connection

Installation