Do not overfi ll the reservoir. It is recommended to keep paper towels on hand just in
case. The liquid coolant should be fi lled up to about 6mm (1/4”) from the reservoir’s
top. This small gap will catch air as it circulates through the system.

Allow the pump to run for about 1-5 minutes. When fi ltration has ended,
the liquid “bubbling” noise should stop. The reservoir level may become
signifi cantly lower during this bleeding process. Before adding more liquid,
remove the ATX Jumper Wire to turn off the pump. (In the future, if you
begin to hear air bubbles rushing through the pump, it may indicate that
more coolant needs to be added.)

Filling & Maintenance

Replace the refi ll plug, slide the reservoir unit
back into the drive bay, and mount it using the
side screws.

The cooling system can be “jump-started” to
assist in the circulation process without boot-
ing-up the computer. This will also allow you to
check your hose connections and make sure
there are no folds or blockages in the tubing.

CAUTION

:

Jumping the incorrect ATX power supply pins can cause

permanent damage to the power supply.

!

Make sure the AC power cord is attached to the power supply. If the power supply
has a rear switch, it must be in the ON (-) position. Using the ATX Jumper Wire,
insert the metal prongs into pin numbers 4 and 6 on the motherboard ATX power
supply connector (green and a black ground wire-- See diagram).

That’s it! Replace the ATX motherboard connection and boot-up the computer.