Disconnecting hoses hose lengths, Cooling system – Koolance RP-1250-R User Manual

Page 12

Advertising
background image

16

17

User Manual

Parallel Loops

Parallel loops are normally used to help accommodate water blocks with
significantly disproportionate flow restriction. They can become quite complicated
and if not well-planned, may lower performance through added bottlenecks and
pressure drop.

One suggestion for parallel loops is to reduce tubing size when splitting. Ideally,
the hose area going into the splitter will be roughly equal to (or slightly lower than)
the combined hose area coming out. For example, 3/8” (10mm) tubing split into
two 3/8” (10mm) paths would lose more pressure than splitting from 3/8” (10mm)
into two or three 1/4” (6mm) paths.

If you are considering a parallel flow path, we would encourage you to experiment
with different setups. There may be more optimal configurations than the example
shown below.

10mm

CPU

Block

Chipset

Block

RAM

Block

Cooling System

(Radiator, Pump, Reservoir)

10mm

Splitter

HD

Block

Chipset

Block

RAM

Block

HD

Block

Splitter

10mm

6mm

6mm

6mm

6mm

6mm

6mm

Installation

Nozzles are designed to attach tightly. If you need to remove a hose for any reason,
it may not pull off easily, even after unscrewing the compression fitting.

Usually, a connection will come free by squeezing the hose on top of the fitting and
twisting/pulling away. If this fails, cutting a small incision lengthwise (parallel) along
the fitting will free it.

When a hose has been removed, it may be distorted. This last portion (about 1cm,
7/16”) should be trimmed to ensure a perfect fit with the next connection. The tip
should always be re-cut if you needed to remove the tubing with an incision.

Disconnecting Hoses

Hose Lengths

Before installing your liquid coolers,
appropriate lengths of tubing must be cut
to connect each device. For computer
cooling, it’s generally easier to estimate
the required amounts with hardware
already mounted.

On the rear of the unit, the inlet and outlet
locations will be labeled. Generally, the
outlet will connect first with your CPU
Cooler or the most temperature-sensitive
device.

Coolant

Outlet

Coolant

Inlet

Advertising
This manual is related to the following products: