Koolance RP-1250-R User Manual

Page 7

Advertising
background image

6

7

User Manual

System Features

PUMP SET

The pump speed can be manually set from 1-10:

PUMP(1-10) 7LV : Pump Speed Level

The pump speed level will flash. Press

▼ or ▲ to adjust.

Press

to return to the

previous menu.

FLOW SET

If a Koolance flow meter (sold separately) has been connected to the slot interface
adapter, configuration is needed to properly display its values. Only one flow meter
can be displayed by the cooling system.

FLOW METER SET
FM-17 ID: 10mm : Flow Meter Model, Tubing Internal Diameter

The Koolance flow meter model number (SKU) will flash. Press

▼ or ▲ to adjust

this based on the following:

• INS-FM16: change to “FM-16”

• INS-FM17, INS-FM17N, INS-FM18: change to “FM-17”

Press

to move to the next option.

The tubing internal diameter (ID) size will

flash. This refers to the hose size attached to the flow meter itself.

Press

▼ or ▲

to adjust this based on the following:

• 6mm (1/4 inch): change to “ID: 6mm”

• 10mm (3/8 inch): change to “ID: 10mm”

• 13mm (1/2 inch): change to “ID: 13mm”

Press

to return to the previous menu.

DISPLAY SET

The display settings configure which values you wish to appear on the front display
and how they are shown:

DISPLAY
FIXED

CYCLIC : Show 2 values or cycle multiple values

The first option, “FIXED”, will flash. Press

◄ or ►

to change between these

options. Press

to configure one of the selections, or press

▲ to exit.

If “FIXED”

is selected, two lines will be shown:

TEMP1 21.7C : First line display option
TEMP1 21.7C : Second line display option

The first line will flash. Press

▼ or ▲ to change what this line will display:

TEMP1 21.7C : Show temperature sensor #1
TEMP2 21.2C : Show temperature sensor #2
TEMP3 20.8C : Show temperature sensor #3
FAN1 1770RPM : Show fan channel #1
FAN2 1640RPM : Show fan channel #2
FAN3 1820RPM : Show fan channel #3
PUMP 5730RPM : Show pump speed
FLOW 4.1LPM: Show flow rate

Press

to confirm. The second line will flash. Press

▼ or ▲ to adjust this line.

Press

◄ to return to the previous menu, or press

to return to the main screen.

When “FIXED” is the chosen display option, line 1 and 2 can be changed quickly
without reentering the DISPLAY SET menu. To do this, briefly press

from the

main screen. The first line will flash:

TEMP1 21.7C : First line display option
PUMP 5400RPM : Second line display option

Press

▼ or ▲ to change what this line will display among the options described

earlier. Press

to move to line 2, and similarly use

▼ or ▲. Press

again to

exit.

If “CYCLIC” is chosen from the DISPLAY SET menu, multiple values will be rotated

through the front display. The first option is whether these values will cycle vertically
or horizontally through the display:

CYCLIC
VERT HORI: Rotate values vertically or horizontally

The first option, “VERT”, will flash. Press

◄ or ►

to change between these options,

press

to configure a selection, or press

▲ to exit.

Choosing either option with

will list all available values:

*TEMP1 21.7C : Show temperature sensor #1
*TEMP2 21.2C : Show temperature sensor #2
*TEMP3 20.8C : Show temperature sensor #3
*FAN1 1770RPM : Show fan channel #1
*FAN2 1640RPM : Show fan channel #2
*FAN3 1820RPM : Show fan channel #3
*PUMP 5730RPM : Show pump speed
*FLOW 4.1LPM: Show flow rate