Chapter, Installation – Koolance RP-1250-R User Manual

Page 9

Advertising
background image

10

11

User Manual

Positioning the Unit

The cooling unit is designed to operate in one orientation. In other directions, the
pump and reservoir may not bleed properly and could lead to cavitation.

YES

NO

Installation

Chapter

2

Installation

Reservoir & Pump Connections

POWER

: Connection from

power supply, 12VDC

FAN

: Radiator fan connections

(2.0A max per plug, 4.5A total)

TEMP

: Temperature sensors

shown on the front display

IN/OUT

: Liquid fitting sockets

The rear of the unit accepts various connections to integrate with your cooling
system.

PUMP

:

Internal
pump

INS-FM17/INS-FM16

:

Connect an optional
flow meter to display
flow rate

ON/SYNC/OFF

:

Adjusts LED lighting
of INS-FM16 flow
meter

ATX

: Wire lead for safety shutdown relay. For computer use,

leave the 2-pin wire connected to “NO” (Normally Open) pins.

If this unit’s relay feature (see: “Alarm and Shutdown Settings”,
pg.4) will be used for an application requiring a Normally Closed
circuit, move wire lead to “NC”.