Technical data – Lenze i700 Manual User Manual

Page 50

Advertising
background image

Technical data

Terminal description
Axis modules

4

l

50

EDS700ACBA EN 4.0

Integrated safety engineering

X1

Labelling

Description

SIA

Safe input, channel A

On double axis devices, there are
two of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.
Independently of this, the
two−channel safe input is always
provided with the channels A
and B.

GS

Reference potential GND

SIB

Safe input, channel B

i700P00x

Terminal data

Conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

flexible

0.2 ... 2.5

24 ... 12

3.5 x 0.6

X1

Electrical data

SIA
SIB
GS

Rated voltage

24 V

in accordance with
IEC 61131−2

Observe detailed
information on
functional safety
(

^ 126).

Voltage range

19.2 ... 28.8 V

Residual ripple

Max.

± 5 %

Current consumption

15 mA

Polarity reversal
protection

When polarity is reversed: no function and no
destruction.

,

Further information on the use of this connection can be found ...

ƒ

in the chapter "Safety engineering" if the "STO" safety function is to be used
(

126).

ƒ

in the chapter "Electrical installation" if safety functions will not be used
(

105).

Advertising