Technical data

Terminal description
Axis modules

4

l

60

EDS700ACBA EN 4.0

Brake connection

X105

Labelling

Description

24E

24 V supply voltage for motor
holding brakes

On double axis devices, there is
one of these connections.
The motor holding brakes of axis
A and B are supplied.

GE

Reference potential GND

i700P00x

Terminal data

Conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

flexible

0.2 ... 2.5

24 ... 12

3.5 x 0.6

X105 Electrical data

24E
GE

Rated voltage

24 V

The supply voltage of
the motor holding
brake must be
independent.
A safely separated
supply is not
required.

^ 85

Voltage range

18 ... 30 V

Current consumption

Corresponding to the connected brake

Terminal current when
looped through

With 1.5 mm

2

: max. 10 A

With 2.5 mm

2

: max. 16 A

Polarity reversal
protection

When the polarity is reversed: no function and no
destruction.

Cable protection

Circuit breaker with tripping characteristic B or C
Standard blade−type fuses

£ 20 A, ³ 30 V

X105

DC 24 V

X105

24E

GE

i700M00x

Fig. 7

Wiring of X105

X105

Supply voltage connection of motor holding brake, can be looped through

A

1−axis module

B

Additionally for 2−axis module

24E

24−V supply voltage for motor holding brakes

GE

Reference potential