Run StockVUE Client by double-clicking on the icon for StockVUE on the desktop.

StockVUE will scan the PC peripherals for the attached SC-1200.

StockVUE main window will now be displayed. Click on the Start button to start reading the load
cells.

After a few seconds, all the load cells will be recognized and will be displayed in a tree structure on
the left of the screen.

At this point, you need to zero out the load cells.

To do this

Make sure the bins are on the load cells and they are all empty.

Right click on the root of the load cell tree and choose ‘Tare All’. You should do this
only when you are sure the bins are empty. Otherwise wrong inventory will be
computed.

Right click again and choose ‘Poll All’ (You can also tare and poll individual load
cells)

Click on

Options…Setup Auto Poll Timings…

to automatically poll the bins at regular intervals.