New Buck Corporation DV1000 User Manual

Page 15

Advertising
background image

DV1000

* 24-1/4”

* 8”

* 20” “From the rear
of the unit to the out-
side wall.”

3/4” WALL BOARD

FIGURE 8/ OPTIONAL REAR VENT TER-
MINATION EXAMPLE.

2” x 4” WALL STUD

3/4” BLACK EXTERIOR WALL BOARD

2” x 4” x 8” BRICK EXTERIOR SURFACE

HORIZONTAL
TERMINATION CAP

9-1/2” WALL

NOTE: This is only an example.
Walls may vary in materials and
construction type.

*

“DIMENSION(S) MUST

BE EXACTLY AS SHOWN
IN THIS EXAMPLE.”

Flex Pipe

This appliance has a rear vent termination option. (you must purchase a DV1000 with this op-
tion
from your dealer) Use termination kit #PP-DVVK-4F-1 only. This installation option can
only be used exactly as shown in figure 5. Follow the direction provided with the termination
kit. (see Horizontal Air Termination Installation page )

CORNER TERMINATION WITH OPTIONAL REAR VENT

20”

20”

The maximum length for a
corner installation is 20”,
with a minimum 8” rise.

8”

OPTIONAL DV1000 REAR HORIZONTAL VENT TERMINATION FIREPLACE

3” min.

1” min.

FILL ANY CRACKS OR GAPS
WITH HIGH TEMPERATURE
CAULK

FIGURE 9

DEFLECTOR SHIELD

Page 12