V-line 32 – Metal Sales V-Line 32 User Manual

Page 2

Advertising
background image

PVL-2

V-LINE 32

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

P

anel

o

verview

PANEL PROFILE

SLOPE

SUBSTRATE

COVERAGE

LENGTH

AVAILABILITY

APPLICATION

FASTENING SYSTEM

FASTENERS

MATERIALS

FINISH

The minimum recommended slope for any V-Line 32 Panel roofing panel is 1:12.

V-Line 32 panel is designed to be utilized over open structural framing, but can easily be used wth a solid

substrate. For solid substrate applications, the recommended substrate is

5

/

8

" plywood with a 30 pound felt

moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure.

V-Line 32 Panel has a coverage of 32" with a 1

3

/

8

" Rib Height.

Lengths under 5'-0" are available with some cutting restrictions. Maximum recommended panel length is 45'-

0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult your

Metal Sales branch for recommendations (see PGI-2 and 3 for locations).

26, 24, and 22 Gauge. Minimum quantities may apply.

Commercial, Industrial panel.

Direct fastened (exposed).

The fastener selection guide should be consulted for choosing proper fasteners for specific applications.

Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14). Note: All

panels are subject to surface distortion due to improperly applied fasteners. Over driven fasteners will cause

stress and induce oil-canning across the face of the panel at or near the point of attachment.

Steel grade 80 for 26 Gauge and grade 50 for 22 and 24 Gauge, per ASTM A-792

*

Acrylic Coated Galvalume

®

(ACG) / ASTM A-792 - AZ55

Prepainted Galvalume / ASTM A-792 - AZ50

**

Fluorocarbon (PVDF)

*

Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection.

**

Meets both Kynar 500 and Hylar 5000 specifications.

C

32" Coverage

1

3

/

8

"

7

/

8

"

3

5

/

8

"

4

9

/

16

"

PERFORMANCE TEST

UL 580, UL 2218, UL 790, Texas Department of Insurance