V-line 32 – Metal Sales V-Line 32 User Manual

Page 7

Advertising
background image

PVL-7

V-LINE 32

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

s

eCTion

P

roPerTies

and

g

eneral

i

nformaTion

C

32" Coverage

1

3

/

8

"

7

/

8

"

3

5

/

8

"

4

9

/

16

"

1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are

effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection. Allowable load

considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or

fasteners/support connection and panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

5’ 6’ 7’ 8’ 9’ 10’ 5’ 6’ 7’ 8’ 9’ 10’

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

32”

60

32”

50

32”

50

26

Ga.

24
22

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

0.91
1.20
1.57

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

Inward

Load

Outward

Load

0.0619 0.0847 0.0619 0.0833

70 52 33 22 16 11 71 53 33 22 16 11

0.0870

0.1217

0.0874

0.1209 102 70 44 29 21 15 103 70 44 29 21 15

0.1163

0.1623

0.1200

0.1683 147 92 58 39 27 20 143 92 58 39 27 20

Slope

Substructure

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

ATTACHMENT DETAIL

FASTENING PATTERN

The minimum recommended slope for V-Line 32 roofing

panel is 1:12. Metal Sales recommends that in all roof

applications sealants be used on all sidelaps with a stitch

screw 1'-0" on center

V-Line 32 is designed to be utilized over open structural

framing or a solid substrate. To avoid panel distortion use a

properly aligned and uniform substructure.

V-Line 32 is available in 1 3/8" rib height with a coverage

width of 32".

Minimum factory cut length is 5'-0". Maximum

recommended panel length is 45'-0". Longer panels

require additional consideration in packaging, shipping, and

erection. Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary loading

and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Acrylic Coated Galvalume

®

, MS Colorfast45

®

, or

various Kynar 500 (PVDF) colors.

Gauges: 24 ga, 26 ga standard and 22 ga optional.

Tape Sealant

1

/

4

"-14 x

7

/

8

" Stitch Screw

(for roof only)

#9-15 x 1" Woodscrew

Tape Sealant

1

/

4

"-14 x

7

/

8

" Stitch Screw

(for roof only)

#9-15 x 1" Woodscrew

Advertising