V-line 32, Ul-580 w – Metal Sales V-Line 32 User Manual

Page 6

Advertising
background image

PVL-6

V-LINE 32

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

1. Metal Roof Deck Panels* No. 26 MSG min gauge, coated steel. Panels continuous over two or more spans. End laps to occur

over purlins with panels overlapped 6 in. with lap beginning 1 in. from purlin web and extending across purlin upper flange. A

line of mastic sealant may be used at panel end and side laps.

METAL SALES MFG CORP

2. Panel Fasteners Fasteners for panel-to-purlin and panel-to-panel connections to be No. 12-14 by 1 in. long self-drilling, self-

tapping, hex-head, coated steel screws with 5/8 in. diam coated steel with bonded neoprene washers.

Spacing to be approximately 9 in. O.C. located in every other panel valley with a fastener located on both sides of the side

lapped rib.

Spacing at the end laps to be the same.

Alternate fastener for panel-to-panel connections; No. 14 by 3/4 in. long self-drilling, self-tapping, hex-head, coated steel

screws with 5/8 in. diam coated steel, bonded neoprene washers may be used. Spacing to be 15 in. O.C.

3. Insulation (Optional) - Any compressible blanket insulation, 4 in. max thickness before compression.

4. Purlins No. 16 MSG min gauge steel (55,000 PSI min yield strength).

5. Lateral Bracing (Not shown) - As required.

Refer to General Information, Roof Deck Constructions (Roofing Materials and Systems Directory) for items not evaluated.

*Bearing the UL Classification Marking

Ul-580 w

ind

U

PlifT

i

nformaTion

Construction No. 187

October 09, 1997

Metal Deck Assemblies

Uplift - Class 90

Fire Not Investigated

V-LINE 32

Underwriters Laboratories Inc.

®

UL

®

LISTED

1

1

1

2

2

2

3

3

3

3

4

4

60.25" Max.

Advertising