MTS Series 793 Application User Manual

Page 229

Advertising
background image

Signal Based Command Process

MTS MultiPurpose TestWare®

Command Processes

229

Signal Based Command (SBC) Process Parameter Descriptions

Note

The SBC process does not support compensation.

A high-speed transition time can result in an unwanted spike (or bump) in
the command signal.

Unwanted command-signal spikes can damage the test specimen.

To avoid spikes in the command signal, use a transition time that smoothly
transitions the channel commands to the initial SBC command level.

Command tab

CAUTION

Command Tab

I

TEM

D

ESCRIPTION

Lookup Table Path/File

Click to display the Open Lookup Table window and select a user-defined text

file containing the lookup data.

Transition Time

Specifies the time the process takes to transition the channel commands to the

initial level. If zero is specified, the transition profile will not be executed.

Duration Time

Specifies the amount of time that the process remains active.

Select the Duration Time check box and enter the amount of time that the
process remains active.

Clear the Duration Time check box to set the duration time to “Indefinite.”