Set Process Parameters in the Procedure Table

MTS MultiPurpose TestWare®

Creating a Practice Test Procedure

167

2. Define the Cyclic Command (Fatigue Part) process.

A. In the procedure table, click the Cyclic Command (Fatigue Part)

process icon.

B. In the Cyclic Command parameters pane, click the Channels tab.

Move all the channels you want to generate the command on to the
Included list. Move all the others to the Available list.

C. Click the Command tab. Type and select the parameters needed for the

test, as shown:

Segment Shape: True Sine, at a Frequency of 1.00 Hertz.

Count (enabled): 100 Cycles

Channel: 10kN Actuator

Control Mode: Force

Absolute End Level 1: 4000 N

Absolute End Level 2: 2000 N

D. Click the General tab and type information as desired.

Cyclic Command