Profile with ALC Process

MTS MultiPurpose TestWare®

Command Processes

233

Profile with ALC Process

About the Profile with ALC Process

The Profile with ALC process works the same as the Profile process. You must
use the Profile with ALC process if you want to play out a profile and use ALC
(arbitrary end-level compensation).

Note

The Profile with ALC process is optional. You must type a special key
code during installation to enable this process.

About ALC

compensation

Arbitrary end-level control (ALC) compensation is an adaptive compensation
technique that improves the tracking accuracy of MPT. ALC compensates for
peak and valley errors by building (and continually updating) a matrix of
amplitude compensation factors.For detailed information about the ALC
compensator, see the MTS 793 Control Software manual.

Profile with ALC Parameter Descriptions

General tab

General Tab

I

TEM

D

ESCRIPTION

Name

Specifies the process name displayed on the Procedure or Group process

window.

Process Enabled

Enables the process. (Clear this box to disable the process.)

Execute Process

Specifies the number of times the process will be run.

Counter Type

Enables a process counter.

Options are None, Transient, or Fixed. Transient counters are displayed only

when the process is active. Fixed counters are displayed throughout the test.

Counter Label

Names the counter.

When you run the test, this name appears under Sequence Counters on the

MPT control panel.

Note

If this box is blank, the process name is used as the counter label.