Cyclic with ALC Process

MTS MultiPurpose TestWare®

Command Processes

241

Cyclic with ALC Process

About the Cyclic with ALC Process

The Cyclic with ALC process works the same as the Cyclic process. You must
use the Cyclic with ALC process if you want to program a cyclic command and
use ALC (arbitrary end-level compensation).

Note

The Cyclic with ALC process is optional. You must type a special key
code during installation to enable this process.

About ALC

compensation

Arbitrary end-level control compensation is an adaptive compensation technique
that improves the tracking accuracy of MPT.

ALC compensates for peak and valley errors by building (and continually
updating) a matrix of amplitude compensation factors.

For detailed information on the ALC compensator, see the MTS 793 Control
Software
manual.

Cyclic with ALC Parameter Descriptions

General tab

General Tab

I

TEM

D

ESCRIPTION

Name

Specifies the process name displayed on the Procedure or Group process

window.

Process Enabled

Enables the process. (Clear this box to disable the process.)

Execute Process

Specifies the number of times the process will be run.

Counter Type

Enables a process counter.

Options are None, Transient, or Fixed. Transient counters are displayed only

when the process is active. Fixed counters are displayed throughout the test.

Counter Label

Names the counter.

When you run the test, this name appears under Sequence Counters on the
MPT control panel.

Note

If this box is blank, the process name is used as the counter label.