MTS MultiPurpose TestWare®

Road Surface Output Process

Command Processes

268

General tab

How to Define a Road Surface Output Process

1. Drag the

icon from the Process Palette to your procedure table.

2. Click the process icon in your procedure table or navigation pane.

3. Click the Command tab.

4. Click the Road Surface File button to open the Select Road Surface file

window. Click the desired drive file, and then click Open.

5. In the Passes box, type the number of passes you want the drive file to

make.

6. Optional—Select Relative Time Signal if you want to enable a relative

(instead of absolute) time signal.

7. Optional—Select Drive has an offset if you want the process to execute the

offset in the drive file.

8. Click the Mapping tab.

General Tab

I

TEM

D

ESCRIPTION

Name

Specifies the process name displayed on the Procedure or Group process

window.

Process Enabled

Enables the process. (Clear this box to disable the process.)

Execute Process

Specifies the number of times the process will be run.

Counter Type

Enables a process counter.

Options are None, Transient, or Fixed. Transient counters are displayed only

when the process is active. Fixed counters are displayed throughout the test.

Counter Label

Names the counter.

When you run the test, this name appears under Sequence Counters on the
MPT control panel.

Note

If this box is blank, the process name is used as the counter label.