Mpt power panel, Mpt power panel 31 – MTS Series 793 Application User Manual

Page 31

Advertising
background image

The MultiPurpose TestWare Interface

MTS MultiPurpose TestWare®

About MultiPurpose TestWare

31

MPT Power Panel

The Power panel displays the hydraulic supply pressure required to run the
selected test.

For more information

See

“MPT Options Editor Execution Tab”

on page 62.

MPT Power Panel

I

TEM

D

ESCRIPTION

To Run

Displays the hydraulic pressure required to run the control channels in the

current procedure (hydraulic pressure options are High, High/Low, Off/

Interlocked, or Off).

Note

Power status applies only to control channels. If a procedure does not
contain control channels, the power status has no effect on the
procedure. For instance, if you remove hydraulic power from a
procedure that does not include control channels, the procedure is still
valid.

You can specify the required hydraulic pressure for the control channels of the

current procedure using the Execution tab of the MPT Options Editor.

Note

You must be in edit mode to change settings on the Execution tab.

The High selection applies to most testing situations. High requires you to

operate MPT with high hydraulic pressure applied to the station’s Hydraulic

Service Manifolds (HSM).

The Off/Interlocked and Off selections are typically used while you are

learning the application software or running test simulations.

The Off/Interlocked selection disregards active interlocks for the sake of

allowing you to run the test unhindered.

Advertising