Failure Detector Process

About the Failure Detector Process

The Failure Detector process is a detector process which monitors signals for
occurrence failure events (peak or valley values), determines whether the failure
events meet the criteria for specimen failure, and if so, completes the process.

Failure Detector Parameter Descriptions

Settings tab

Settings Tab

I

TEM

D

ESCRIPTION

Failure Event

% of

event type
(Maximum or
Minimum
)

monitored signal

Specifies the percentage of the monitored signal’s maximum or minimum

value that represents specimen failure. When the monitored signal reaches this
level the process ends.

Selects the type of event the process looks for in the monitored signal. For
example, if you select maximum, a maximum or peak level will trigger the

process.

Selects the input signal for which the process monitors your failure criteria.

Initial Value

Specifies whether the process monitors the value of the selected signal relative
to zero (Absolute), or relative to the value of the signal when the Failure

Detector process started (Relative).

Sensitivity

Specifies how much the monitored signal must change before a level is
considered a maximum event (peak) or a minimum event (valley).