Limit Settings Window

All limit adjustments are made within this window. For each channel, you can
select Lower Limit, Upper Limit, and Limit Action.

Example of signals displayed in the Limit Settings window.

Limit Settings Window

I

TEM

D

ESCRIPTION

Prints the current limit settings in a tabular form.

Applies the selected action to all channels, and redisplays the Trend

Monitoring window.

Active Process

Selects the desired process or file.

Upper/Lower Limit

For a data file: Displays the limit values.

For a procedure file: Displays editable limit values. To edit them, double-click

a value, then type the new value. Press the Enter key to accept changes.

Limit Action

For a data file: Displays the action settings.

For a procedure: Displays editable action settings. To change a setting, double-

click it. A list appears with the following options:

None—Limit is disabled.

Warning—A warning message is issued and a message is written to the MPT

Message Log.

Stop—The process stops and a message is written in the MPT Message Log.

Trigger—The process triggers another process.

Status bar

Displays the name, dimensions, and full scale of the selected channel.