3.2-c: Installing the Capacity Monitor Faucet

NOTE: In addition to the blue plastic tubing attached to the faucet.
A separate piece of blue tubing is included for connection between the
housing OUTLET port and the Filter Monitor Unit.

1. From the sink / countertop:

a. Place the leD Display Plate (#7) over the faucet hole.
b. Feed the attached black wire (#8) down through the faucet hole. rotate

the leD Display Plate so that the indicator light will be easy to see.

c. Place the faucet base (#3) on top of the leD Display Plate. Feed the blue

tubing and faucet stud down through the hole in the sink. The faucet stud
should now be accessible below the sink.

2. From under the sink:

a. slide the black track washer (#10) (with the flat side down) upward over

the threaded faucet stud. Guide the black wire (#8) from the leD Display
Plate through the track to protect the wire and prevent it from becoming
pinched between the sink and the stud nut.

b. slide the hard plastic black washer (#11) upward over the blue tubing (#5),

and faucet stud (#4).

c. slide the lock washer (#12) upward over the faucet stud, below the black

plastic washer.

d. screw on the stud wing nut (#13) below the lock washer.
e. Hand-tighten the wing nut to secure the faucet.

when the Aquaperform is installed with a capacity monitor, the DigiFlow 5000V Capacity Monitor (MC993) flashes red when
the filter should be changed. Two AAA batteries (not included) are required for capacity monitor operation. The Capacity
Monitor consists of two main parts, the leD Display Plate that sits below the faucet, and the Filter Monitor unit (FMu) that
connects in-line between the drinking water system housing and the faucet.

1 spout
2 faucet handle
3 faucet base
4 faucet stud
5 tubing (blue) attached to faucet
6 smaller rubber washer
7 leD display plate
8 black wire

(attached to #7)

9 larger rubber washer
10 black track washer
11 hard plastic black washer
12 lock washer
13 wing nut
14 filter monitor unit
15 two adapters

(MC744)

Faucets with Capacity

Monitor include:

Countertop

tubing from

housing

Installation Overview

tubing from

faucet

Filter Monitor unit

black wire from capacity

indicator plate

Capacity Monitor

Assembly

4

5

7

8

9

10

11

12

13

countertop

countertop

1

2

3

6

14

5

15

15