Attach the Adapters to the Housing

1. Connect the included Inlet adapter (MC720) to the system housing’s labeled Inlet port.

rotate the adapter clockwise, first by hand, then using a wrench, to tighten onto the
system.

2. Connect the included Outlet adapter (MC720) to the system housing’s labeled Outlet

port. rotate the adapter clockwise, first by hand, then using a wrench, to tighten onto
the system.

1. using wire cutters or a knife, cut (square cut) the tip end off of the blue plastic tubing

(either connected to the faucet or a separate piece included with the Capacity Monitor).
Do not use scissors.

2. Fully insert the tubing into the adapter on the OuTleT port of the system housing; the

tubing should typically be inserted 5/8” into the adapter.

nOTe: when pushing the tubing into the adapter, you will encounter some resistance.
This does not mean that the tube is fully inserted. Continue to push firmly until the tubing
is inserted as far as possible (roughly 5/8” into the adapter).

3. Pull on the tubing to make sure that it is securely connected.

Housing Top

Insert tubing and push until you
feel resistance -- at this point,
the tubing is not fully inserted.
Push firmly until the tubing is
inserted as far as it will go.

15

3.4: Connecting the Tubing to the Housing

Connect the Tubing to the Outlet Port

blue tubing

OuTleT

Adapter

OuTleT

InleT

Connect the Tubing to the Inlet Port

1. using wire cutters or a knife, cut (square cut) the tip end off of the clear plastic tubing con

nected to the Adapta Valve. Do not use scissors. Do not cut more than 1/2" off of the
end of the clear plastic tubing.

2. Fully insert the tubing into the adapter on the InleT port of the system housing; the

tubing should typically be inserted 5/8” into the adapter.

nOTe: when pushing the tubing into the adapter, you will encounter some resistance.
This does not mean that the tube is fully inserted. Continue to push firmly until the tubing
is inserted as far as possible (roughly 5/8” into the adapter).

3. Pull on the tubing to make sure that it is securely connected.

clear tubing

InleT

adapter

Connecting to straight Adapter

Insert tubing and

push until you feel

resistance -- at this

point, the tubing is

not fully inserted.

Push firmly until the

tubing is inserted as

far as it will go.

Insert blue tubing 5/8”