MAYCO LS400/LS500 PUMP — OPERATION AND PARTS MANUAL — REV. #6 (09/19/11) — PAGE 27

2. Turn the

Cylinder Stroke Control Switch to the

AUTOMATIC position (Figure 20).

3. Place the

Pumping Control Switch to the CENTER

OFF position (Figure 21) for normal pumping operation.

Figure 19. Emergency Stop Switch

E

m

er

gency S

to

p

LS400/LS500 PUMP — START-UP PROCEDURE

DO NOT attempt to operate this concrete pump until
the Safety, General Information and Inspection
sections have been read and understood.

STARTING PROCEDURE

If the Emergency Stop switch is in the
CLOSED position (stop), engine will not start.
To star t the engine, make sure the
Emergency Stop switch is in the OPEN
position (fully extended).

WARNING - GENERAL SAFETY GUIDELINES

1. Locate the Emergency Stop Switch (Figure 19) on the

Hydraulic Pump Control Box. Turn the Emergency Stop
switch clockwise and release (open). This will allow the
engine to start.

Figure 20. Cylinder Stroke

Control Switch (Automatic)

5. To start the engine, insert the key (Figure 23) into the

ignition switch and turn the key to the ON position.

6. When the ignition key is in the ON position, the Digital

Readout Screen (primary) will cycle through 3 displays
as shown in Figure 24.

LOCAL

REMOTE

CENTER

OFF

4. Place the

Direction Control Switch to the FORWARD

position (Figure 22).

AUTOMATIC

JOG

Figure 21. Pumping Control Switch (OFF)

FORWARD

REVERSE

Figure 22. Direction Control Switch (FORWARD)

Figure 23. Ignition Switch

7. Turn the key to the START position and listen for the

engine to start. In warm weather let engine warm up for
5 minutes. In cold weather let engine warm up for 10
minutes.

LS 400 OFF
0000 ENG RPM
BATTERY 12.5 V
LOW OIL PSI

1

LS 400 OFF
0000 ENG RPM
BATTERY 12.5 V
LOW RPM FAULT

1

LS 400 OFF
0000 ENG RPM
BATTERY 12.5 V
END OF MESSAGE

1

Figure 24. Primary Screen (Ignition Key ON)

Advertising