MAYCO LS400/LS500 PUMP — OPERATION AND PARTS MANUAL — REV. #6 (09/19/11) — PAGE 31

It will be necessary at times to move your pump from
one job site location to another. Before moving the
pump, make sure to pump the remaining concrete out
of the hopper. Moving the pump with a

full hopper of

concrete can cause

severe damage or breakage of

the axle and axle springs, excess strain and pressure
on the hub and bearing assembly.

WARNING - TRANSPORTING PUMP

Leaking manifold seals or hose coupling
gaskets which leak water can cause separa-
tion and subsequent jamming at that point.

LS400/LS500 PUMP — OPERATION

Cable Remote Control

Installation of the Cable Remote Control Assembly

Connect the cable to the front panel of the control box (See
Figure 38).

CABLE REMOTE CONTROL UNIT

CABLE REMOTE CONTROL UNIT

25 FT. CABLE

25 FT. CABLE

PUMP REV

PUMP ON/OFF

TO CONTROL BOX
CONNECTOR

TO CONTROL BOX
CONNECTOR

Figure 38. Cable Remote Control

Radio Remote Control Programming

Before starting operation of the Radio Remote Control, go
to Screen 9 of the Digital Readout Screen:

1. Press the ON/OFF button on the radio (wireless) remote

control to turn on the power. Hold down the RESET
switch. The display will now show:

2. After 5 seconds, the display will show:

3. The remote control is now ready for use.

RADIO ADDRESS
NO RADIO
PRESS RESET TO
LEARN A NEW ONE

9

RADIO ADDRESS
NOW SCANNING
FOR NEW
TRANSMITTER

9

Cable Remote Control Operation

Before using cable remote control, set the pumping volume
with the VOLUME switch on the control box then move the
Pumping Control Switch on the control box to the REMOTE
position.

The cable remote control (Figure 38) has the following
controls.

PUMP ON/OFF - Starts and stops the forward pumping.

PUMP REV - starts pumping in reverse direction.

RADIO ADDRESS
COMMUNICATING
PRESS RESET TO
LEARN A NEW ONE

9