APPENDIX — RECOMMENDED SHOTCRETE SYSTEM

GENERAL RECOMMENDATIONS
■ If the site will permit, use steel pipe from the pump to

the pool perimeter. It will reduce line pressures which is
highly recommended.

■ The vibrator on the reducer by the pool improves

pumpability.

■ Turn both air vibrators off whenever the pump is stopped

to prevent separation of mix.

■ The air vibrators are low consumption (4.2 scfm).
■ Leave the air on at the nozzle when the pump is stopped

to prevent clogging of air the hoses in the air insert.

■ Use item #11 (steel elbow) at the edge of the pool to

prevent collapse of the rubber hose, which can cause
blockage.

RECOMMENDED SHOTCRETE SYSTEM

NO.

PART NO.

PART NAME

QTY.

REMARKS

1

EM28906

COUPLING, 5” H-D “CF”

2

EM25837

ELBOW, 5"x4”x90°

3

EM28905

COUPLING, 4” H-D w/GASKET & PIN

4

EM402552

REDUCER, 4”x2.5”x53” H-D ENDS

5

EM28061

PIPE, 2.5”x120w x 10’ H-D

6

EM289035

COUPLING, 2.5” H-D w/GASKET & PIN

7

EM28001DD

REDUCER, 2.5”x2”x36” H-D

8

EM23815D

REDUCER, 2.5”x2” w/AIR VIBRATOR

9

EM28902

COUPLING, 2” H-D w/GASKET & PIN

10

EM23101

AIR VIBRATOR ASSY.

11

EM28131D

2"x2" ELBOW 90º

12

EM24841

HOSE, 2”x25’ H-D w/ENDS

13

EM23808D

NOZZLE ASSEMBLY, 2” H-D

14

EM23806

NOZZLE TIP, RUBBER 1-3/8”

15

EM23807

NOZZLE TIP, RUBBER 1.25”