Analog connections overview – Pololu Simple User Manual

Page 41

Advertising
background image

Simple High-Power Motor Controller 18v15 or 24v12 analog

connections.

Simple High-Power Motor Controller 18v25 or 24v23 analog connections.

Analog Connections Overview

The analog connection block consists of two channels. Each channel has a signal pin and a + and pin for powering
the analog voltage source. These potentiometer power pins are special in that they allow the Simple Motor Controller
to detect if an analog channel has become disconnected, so we recommend using these pins rather than alternate
power supplies or other pins on the board.

If you use an analog voltage source that is not powered from the Simple Motor Controller’s
potentiometer power (+ and ) pins, you will need to check the Ignore Pot Disconnect checkbox under
the Advanced Settings tab of the Simple Motor Control Center (see

Section 5.3

).

We recommend using a potentiometer in the 1 kΩ to 10 kΩ range. Higher-resistance potentiometers will not work
well with the potentiometer disconnection detection feature. If you need to use a higher-resistance potentiometer, you
can disable potentiometer disconnection detection from the Simple Motor Control Center.

Pololu Simple Motor Controller User's Guide

© 2001–2014 Pololu Corporation

4. Connecting Your Motor Controller

Page 41 of 101

Advertising