Bunn CWTF User Manual

Page 16

Advertising
background image

Page 16

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic

Technical Service Department.

• Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-

nel.

• All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of

terminals or the application of external voltages may result in board failure.

• Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If

an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a

terminal or crimp.

• Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are

energized for more than ten minutes without a supply of water.

• The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will

help to avoid twists and kinks in the tubing.

• Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

• This brewer is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the brewer when servicing, except when electrical tests are specified.

• Follow recommended service procedures

• Replace all protective shields or safety notices

PROBLEM

Brew cycle will not start

Water is not hot

Inconsistent beverage level

Consistently low or high bever-

age level.

PROBABLE CAUSE

1. ON/LOWER Switch is off.

2. No power

3. No water

1. Heater switch turned off.

1. Lime Build-up

2. Water Pressure fluctuating.

1. Timer adjustment.

REMEDY

Turn on switch.

(A) Turn on main power switch.

(B) Check that the power cord is

securely plugged into outlet.

(C) Check circuit breakers or

fuses.

(A) Water lines and valves to the

brewer must be open.

(B) Check for plugged water filter

Turn on switch

(A) Use deliming spring.

(B) Clean sprayhead. (Page 11)

Have a pressure regulator In-

stalled.

Adjust timer (Page 10)

41721 111308