TROUBLESHOOTING (cont.)

PROBLEM

Spitting or excessive steaming

Dripping from sprayhead

Brew cycle starts when ON/

LOWER Switch is turned on.

Weak beverage

Dry coffee grounds remain in

the funnel

PROBABLE CAUSE

1. Lime Build-up

1. Syphon System

Auxiliary brew start switch on

TWINS inadvertently activated.

1. Filter Type

2. Coffee Grind

3. Sprayhead

4. Funnel Loading

5. Water Temperature

1. Funnel Loading

2. Sprayhead

REMEDY

(A) Use deliming spring.

(B) Clean sprayhead. (Page 11)

The brewer must be level or

slightly lower in front to syphon

properly.

Move objects away from brewer.

BUNN® paper filters must be used

for proper extraction.

A fine or drip grind must be used

for proper extraction.

A clean spray-head must be used

for proper extraction.

The BUNN® paper filter must be

centered in the funnel and the

bed of ground leveled by gentle

shaking.

Place an empty funnel on an empty

dispenser beneath the sprayhead.

Initiate a brew cycle and check the

water temperature immediately

below the sprayhead with a ther-

mometer. The reading should not

be less than 195°F (76°C). Adjust

the control thermostat to increase

the water temperature. Replace if

necessary.

The BUNN® paper filter must be

centered in the funnel and the

bed of grounds leveled by gently

shaking.

A clean spray-head must be used

for proper extraction.