Your Hardness test results may indicate “Grains”, “PPM”, or “mg/L”. It is

important to note that PPM and mg/L are the same measure and both figures can

be treated interchangeably. If you get a hardness figure in PPM or mg/L, please

divide this number by 17.1 to get Grains.

Ex: If your hardness is measured at

300 PPM, your Grains are 300 / 17.1 = 18 Grains.

Your Iron results should also be measured in either “PPM” or “mg/L”. Add your

level of iron multiplied by 5. Add this number to your hardness level. This final

figure will be your Total Hardness Level that we will program into your softener

system.

Ex: If your iron level is measured at 5 PPM, add 5 x 5 = 25 Grains of

hardness to existing hardness total.

To begin programming, first plug in your 5600SXT Valve to a nearby wall outlet.

The system will illuminate 4 digits. The system will show the time of day and the

amount of gallons remaining. This display will switch between these valves about

every 10 seconds.

Set the time on the system to 12:01 PM by pressing either the “UP” or “DOWN”

arrow as shown in figure 23 below. You may hold the button to allow the time to

scroll faster.

Once the time display is set to 12:01 PM, press the “extra cycle” button once as

shown in figure 24 below.

FIGURE 23

FIGURE 24

To enter master programming mode, press the “UP” and “DOWN” buttons

TOGETHER and HOLD for 5 seconds, and then release the buttons, as shown in

figure 25 below.

The display should now show “DF / GAL” as shown in figure 26 below. (This

indicates U.S. Operation Mode - Gallons)

Do not change this value, and press

the “Extra Cycle Button” once to continue

.

FIGURE 25

FIGURE 26