The display should now show “RS / SF” as shown in figure 32 below. (This

indicates Reserve Selection is Safety Factor percentage)

Do not change this

value, and press the “Extra Cycle Button” once to continue

.

The display should now show “SF / 20” as shown in figure 33 below. (This

indicates the Safety Factor is 20 percent)

Use the “UP” or “DOWN” button to

change this value to “15”, and press the “Extra Cycle Button” once to
continue when finished.






FIGURE 32

FIGURE 33

The display should now show “DO / 14” as shown in figure 34 below. (This

indicates the Day Override is 14 days – the system will regenerate on the 14

th

day

if the meter does not otherwise automatically initiate a regeneration based on

usage.)

Do not change this value, and press the “Extra Cycle Button” once to

continue.

The display should now show “RT / 2:00” as shown in figure 35 below. (This

indicates the system will regenerate at 2:00 AM, assuming the system clock is set

accurately)

Although this is the recommended time, you may change this by

using the “UP” or “DOWN” buttons, and then press the “Extra Cycle
Button” once to continue.





FIGURE 34

FIGURE 35

The display should now show “BW / 10” as shown in figure 36 on the following

page. (This indicates Backwash Time is 10 minutes in length)

Do not change this

value, and press the “Extra Cycle Button” once to continue

.

The display should now show “BD / 60” as shown in figure 37 on the following

page. (This indicates Brine Draw Time is 60 minutes)

Do not change this value,

and press the “Extra Cycle Button” once to continue

.