INSULATING SHEATHING FOR RESIDENTIAL CONSTRUCTION APPLICATION GUIDE

39

06. Punched Window Interface

– Installation Sequence

Step 1: Wood frame wall sheathed with OSB
or plywood with housewrap as drainage
plane.

Step 2: Modified “I” cut in housewrap over
framed opening (dashed line above)

Step 3: Housewrap folded in at jambs and sill
and secured tightly. Head flap folded
outward; or, tuck head flap under

Step 4: Install first piece of sill pan into
horizontal slit in housewrap. Pan must fit
tightly. Fasten at vertical face of pan only.

Step 5: Slip second piece of sill pan into
horizontal slit in housewrap; pan must fit
tightly. Fasten only at exterior vertical face.
Ensure a minimum 3” overlap at sill

Step 6: Tape or flash sill pan at jambs and sill
joint