Table 3 vent manufacturer contact information – Bosch AQUA STAR 2400E LP User Manual

Page 12

Advertising
background image

6 720 608 263

12

Installation instructions

may result in a hazardous condition. For specific
questions concerning vent material, specifications,
usage or installation, contact the vent manufacturer
directly.

Vent Safety System

The 2400 E will shut down if inadequate exhaust
venting is detected or a lack of combustion air is
provided to the unit. See troubleshooting section on

page 33. Correct the problem and then reset the heater
before operating.

3.6.2

Vent connections

Exhaust vent connection

B Attach the flue gas exhaust accessory (8 705 504

137) to the top of the unit (position 1) using the 4
screws and gasket provided.

B Insert single wall stainless steel vent pipe into the

exhaust vent adapter 1.5” and tighten the clamp ( Fig.
10 position 2).

Note: 3 to 4 inch increaser required when using 4 inch
pipe.

Note: Failure to fully insert vent pipe and tighten clamp
may cause flue gas leakage or condensate damage that
is not covered under the manufacturer's warranty.

Fig. 10 Exhaust vent connection

Combustion air inlet connection

The combustion air inlet accessory can be connected
either to the top right or left of the appliance. The
unused side must be sealed.

B Attach the combustion air inlet accessory (8 705

504 115) to the top of the unit (position 3) using the
3 screws and gasket provided.

B Install combustion air pipe over the air inlet acces-

sory. If using flexible piping, secure with a clamp
(position 4, not included).

Fig. 11 Combustion air inlet connection

Vent manufacturer

Contact information

Z-flex

www.z-flex.com
800-654-5600

ProTech Industries

www.protechinfo.com
800-766-3473

Heat-Fab

www.heatfab.com
800-772-0739

Table 3 Vent manufacturer contact information

Z flex

ProTech

Heat Fab

3” Venting

3” Horizontal

termination

2SVSTB03

FSTB3

9390 TEE

3” Vertical

termination

2SVSRCF03

FSRC3

5300CI

90°

Condensate

Drain Tee

2SVEVWCF03

FST3 &

FSDF3

93PPLSTEE

Horizontal

Condensate

Drain

2SVEDWCF03

FSHDT3

9321

Vertical

Condensate

Drain

2SVSEVDP03

N/A

N/A

Condensate

Drain Tube

2SVEDTK

N/A

7000TUBE

4” Venting

3” to 4”

Increaser

(Required)

2SVI0304

FS0304TI

9374

4” Horizontal

termination

2SVSRTF04

FSTB4

9490TEE

4” Vertical

termination

2SVSRCF04

FSRC4

5400CI

90°

Condensate

Drain Tee

2SVEVWCF04

FST4 &

FSDF4

9416 &

9417D

Horizontal

Condensate

Drain

2SVEDWCF04

FSHDT4

9421

Vertical

Condensate

Drain

2SVEVDP04

FSUCD4

N/A

Condensate

Drain Tube

2SVEDTK

N/A

7000TUBE

Table 4 Approved vent termination and condensate

drain part numbers (subject to change)