Bosch AQUA STAR 2400E LP User Manual

Page 17

Advertising
background image

6 720 608 263

Installation instructions

17

Recommended exhaust vent terminator clearances

Fig. 17

* Subject to local codes and anticipated snow level

** Other equipment that operates with a mechanical air inlet may require greater distances, reference manufacturer's instructions

NOTE: terminating exhaust vent under a deck is not recommended

Ref.

Description

Minimum distance

A

Directly below an opening; operable windows, doors and any non-
mechanical fresh air openings

36 in (twin pipe installation)

48 in (single pipe installation)

B

Below a gutter, sanitary pipework or eaves

24 in

Below a gutter, sanitary pipework or eaves, protected by metal
shielding

12 in

C

From any internal corner

12 in

D*

Above ground or snow pack

12 in

Above a paved sidewalk

7 ft

E

From an opposing wall or structure facing the termination

24 in

From the relief valve of a gas regulator

36 in

F

From a terminator facing a terminator

48 in

G

Vertically between two exhaust vent terminators on the same wall

60 in

H

Horizontally between two exhaust vent terminators on the same wall

12 in

I**

Horizontally and vertically from combustion air inlet of a twin pipe
system

36 in

From the gravity combustion air inlet any other equipment

48 in

J

From any external corner

12 in

K

Horizontally from an opening; operable windows, doors and any non-
mechanical fresh air openings

12 in (twin pipe installation)

48 in (single pipe installation)

L

Vertically from a wall, roof slope, or obstruction (venting through a flat
or pitched roof)

see Chapter

3.6.5

Table 6