Faults - Solutions

E

1

4

F

AULTS

S

OLUTIONS

The unit does not lit up

Check

- unit/power supply connections
- fuses supply line

Flow rate test

Check

- calibration factor
- shutters are closed

Repeat the calibration test

Shutters open to maximum then to minimum

Check

- Tractor drive rate coefficient.
- spreading width
(24.00, beware of the decimal sign)

The unit lits up but the rams do not move

Check

- Fuses

Area counter reading incorrect

Check

- connection / machine
- working width
- drive rate

Flow rate

Check

- programmed flow rate
- fertiliser coefficient
- PDF rate = 540 RPM
- spreading width
- tractor drive rate
- shutter opening/closing performance
- ram travel
- peg marking

The drive rate is incorrect

Check

- connection on unit
- sensor magnet clearance
- magnet rotation
- sensor wire continuity

(100

Ω ± 10)

- 100-m coefficient

Tonnage counter reading incorrect

Check

- connection / machine
- working width
- drive rate
- fertiliser coefficient
- shutter opening/closing