Cleaning the condenser

The condenser should be cleaned at least three
times a year. If you have pets, the condenser must
be cleaned more frequently.

1. Turn off the main power switch.

2. Replace the lower plinth.

3. Open the condenser panel by turning the two

knobs counterclockwise.

4. Remove the condenser and rinse the lamella

springs clean, using a hand-held shower, for
example. Do not touch the lamella springs, as
you may damage the condenser. Do not use
pointed metal objects during cleaning.

NOTE!

Do not put the condenser in a dishwasher.

5. Wipe any lint from the compartment for the

condenser as necessary. Use a cotton bud or
similar item to remove any lint from the drain
hole [A] and the channel [B].

[ ]

A

[ ]

B

6. Replace the condenser. When refitting the

condenser, check that it is replaced correctly.
The top of the condenser is marked "upp",
"up", and "oben".

UPP

UP

OBEN

7. Replace the plinth.