Summit PRO24G User Manual

Page 18

Advertising
background image

Test Broil Burner Flame. While the
burner is lit, inspect the flame. See
flame figures below for proper flame
characteristics. If the flame burns
completely or mostly yellow, adjust the
broil burner air shutter.
Replace oven bottom cover. Slide cover
into place and replace two rear thumb
screws.

Flame Characteristics
Yellow flames:
Further adjustment is required.
Yellow tips on outer cones:
Normal for LP gas.
Soft blue flames:
Normal for natural gas.

If the flame is completely or mostly
yellow, verify that the regulator is set for
the correct fuel. After adjustment,
retest.
Some yellow streaking is normal during
initial start-up. Allow unit to operate 4-5
minutes and re-evaluate before making
adjustments.

Call Service if:
1. Any of the burners do not light.
2. The broiler burner or bake burner

flame goes out before reaching
350°F.

3. Any of the burners continues to burn

yellow.

If flame adjustment is necessary,
continue to next page. Otherwise,
installation is complete at this point.

Gas Conversion

This appliance can be used with LP gas
and natural gas. It is shipped from the
factory adjusted for use with natural gas.
Conversion orifices are located in the
conversion kit. Follow the instructions

packed with the orifices for gas
conversion.

CAUTION:

Risk of explosion!

Before starting any work on the gas
installation, please shut off the gas
supply.
In order to change your appliance's gas
type, change all injectors and make
flame adjustment for all valves at
reduced flow rate position.

Exchange injector for the burners
1. Take off burner cap and burner body.
2. Unscrew injectors.
3. Fit new injectors.
4. Check all connections for secure

fitting and tightness.

NOTICE
New injectors have their position

marked on their packing, or pressure
table on page 34 can be referred to.





1 Flame failure device
2 Spark plug
3 Injector
4 Burner

CAUTION:
Unless there is an abnormal condition,

do not attempt to remove the gas
burner taps. You must call an
authorized service agent if it is
necessary to change the taps.

Reduced gas flow rate setting for
range taps
1. Ignite the burner that is to be adjusted

and turn the knob to the reduced
position.

17

Advertising