Regency B36XTCE Gas Fireplace

INSTALLATION

HORIZONTAL TERMINATIONS

FLEX VENT 5" X 8"

These venting systems, in combination with the B36XTCE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations Diagram in "Exterior Vent
Termination Locations" section.

Regency

®

Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) includes all the parts needed to install the B36XTCE with a either

a top or rear vent.

Note: If top venting this unit, the 5" x 8" venting may only be used if venting to the minimum of 42-1/3" to centerline.
No other application is approovred.

1) 8"

dia.

fl exible liner (4 ft. length)

2) 5"

dia.

fl exible liner (4 ft. length)

3) spring spacers (4)
4) thimble
5) AstroCapXL termination cap (1)
6) screws

(12)

7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,

Stainless Steel (4)

10) vinyl siding standoff

Notes:

1) Liner sections should be continuous without any joints or seams.

2) Only Flex pipe purchased from Regency may be used for Flex installations.

3) Regency

®

Direct Vent System (Flex) is only approved for horizontal terminations.

Note: If longer runs are required - rigid pipe must be used.

FPI Kit #

Length Contains:

#946-615

4 Feet

1) 8”

fl exible liner (Kit length)

2) 5”

fl exible liner (Kit length)

3) spring

spacers

4) thimble
5)

AstroCap termination cap

6) screws
7)

tube of Mill Pac

8) plated

screws

9)

S.S. screws #8 x 1-1/2” drill point

10) vinyl siding standoff