Regency B36XTCE Gas Fireplace

INSTALLATION

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.

Minimum Air Shutter Opening:

NG 1/4"

LP 3/8"

CAUTION: Carbon will be produced if air shutter

is tightly closed.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT covered
under warranty.

Air shutter rod - located to the left

of the valve assembly.

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.

(Do not cut the ground terminal off under any circumstances.)

NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case

the fan is installed at a later date.

PROFLAME SYSTEM WIRING DIAGRAM

CONFIGURATION: 886 ON/OFF STAND ALONE

0.886.001

Proflame Valve

Standard Main On/Off Switch
or Optional Wall Switch

Note: 4 AA batteries must be installed to operate
the burner switch.
Do not use a 9 volt battery.

SureFire™ Switch

IMPORTANT:

If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in the

receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.