Installation, Bulb replacement, Line voltage wiring to receptacle in unit – Regency Bellavista B36XTCE Medium Gas Fireplace User Manual

Page 60

Advertising
background image

60

Regency B36XTCE Gas Fireplace

INSTALLATION

18) Reinstall the logs.

19) Reinstall glass door and bottom louver / full screen doors.

20) Plug the light assembly into the receptacle located on the
bottom left side of the unit.

21) Turn on electrical supply - test lights.

1) Follow steps 1- 4 from previous page.

2) Remove 2 screws to remove light diffuser plus gasket.

3) Replace the bulb - do not touch bulb with bare hands, use gloves or bulb
packaging to protect bulb.

4) Reinstall the gasket and light diffuser.

5) Reverse steps 4-1.

Ground Wire

Receptacle

BULB REPLACEMENT

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(mobile home

approved)

Star washer

Ground

Green

Neutral

Live

Black

Red

Red

Minimum Convection

Air Temp. Switch

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan

Optional Fan

Light

Switch

Receptacle

in Unit

To Fan (see above)

Optional Accent Light

Ground

L1

N

Black

Red

Ground

Break Tab

Copper terminals

Black

Do Not Break Tab

on Neutral (silver terminals)

Fan

Switch

Green

ELECTRICAL WORK MUST BE
PERFORMED BY A QUALIFIED
ELECTRICIAN

LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT

TO MAKE OUTLETS INDEPENDENT OF EACH OTHER

Advertising