Operating instructions, Shutdown procedure, First fire – Regency Hampton H35 Large Gas Stove User Manual

Page 40: Final check, Lighting procedure

Advertising
background image

40

Hampton® H35-2 Direct Vent Freestanding Gas Stove

40

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1) Read and understand these instructions

before operating this appliance.

2) Check to see that all wiring is correct and

enclosed to prevent possible shock.

3) Check to ensure there are no gas leaks.

4) Make sure the glass in the door frame is

properly positioned. Never operate the ap-
pliance with the glass removed. Never strike
the glass or slam the door shut.

5) Verify that the venting and cap are unob-

structed.

6) Verify log placement. If the pilot cannot be

4) When the pilot stays lit, turn the gas knob further

counterclockwise to the "ON" position.

5) Use the thermostat or remote control to turn on

the unit.

6) Rotate

the

fl ame height regulator to adjust the

fl ame height higher or lower.

SHUTDOWN

PROCEDURE

1) Use the thermostat or remote control to turn off

the main burner.

2) Turn the main gas control clockwise to the

"OFF" position to turn off the pilot (push knob
in slightly).

3) Turn off all electric power to appliance if service

is to be performed.

FIRST FIRE

The FIRST FIRE in your stove is part of the paint
curing process. To ensure that the paint is properly
cured, it is recommended that you burn your fi replace
for at least four (4) hours the fi rst time you use it with
the fan on. When fi rst operated, the unit will release
an odour caused by the curing of the paint and the
burning off of any oils remaining from manufactur-
ing. Smoke detectors in the house may go off at this
time. Open a few windows to ventilate the room for
a couple of hours. The glass may require cleaning.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE

IT IS STILL HOT!

Note: When the glass is cold and the appliance

is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.

DO NOT BURN THE APPLIANCE WITH-
OUT THE GLASS FRONT IN PLACE.

During the fi rst few fi res, a white fi lm may
develop on the glass front as part of the cur-
ing process. The glass should be cleaned or
the fi lm will bake on and become very diffi cult
to remove. Use a non-abrasive cleaner and
NEVER clean the glass while it is hot.

seen when lighting the unit - the logs have
been incorrectly positioned.

7) The unit should never be turned off, and on

again without a minimum of a 60 second
wait.

2) Connect the wires as per the wiring diagram

below.

CAUTION

Do not connect the

millivolt remote control wires

to the 120V wires.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:

1) Clocking the appliance to ensure the cor-

rect fi ring rate (rate noted on label) at 15
minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.

3) Check for proper draft.

CAUTION

Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility
of the manufacturer.

LIGHTING

PROCEDURE

IMPORTANT: Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.

1) Turn stove OFF using the Burner "ON/OFF"

switch remote or thermostat.

2) Turn gas control knob so indicator points

to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.

3) Turn gas control knob counterclockwise

so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button several times until the
pilot lights. After approximately one minute,
release the gas control knob. The pilot fl ame
should continue to burn. If the pilot does not
remain lit, repeat operation allowing a longer
period before releasing gas control knob.

IMPORTANT

To ignite or reignite the pilot,

the door to the fi rebox must

be opened.

Only when the pilot holds, without pressure
being applied to the control knob, should the
door to the fi rebox be closed. The unit must
never
be operated with the glass or door
open.

NOTE: For all propane units and units
equipped with electric spark boxes, see
"Copy of Lighting Plate Instructions" sec-
tion for more details.

Advertising