Safety label, Copy of safety label – Regency Hampton H35 Large Gas Stove User Manual

Page 5

Advertising
background image

Hampton® H35-2 Direct Vent Freestanding Gas Stove

5

SAFETY LABEL

This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.

NOTE: Hampton

®

units are constantly being

improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.

COPY OF SAFETY LABEL

Listed: VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION

Certifi ed for/Certifi ée pour: CANADA and U.S.A.
WN# 16478
Tested to: CGA 2-17-M91, ANSIZ21.88a-2007/CSA 2.33a-2007

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

DO NOT REMOVE THIS LABEL / NE
PAS ENLEVER CETTE ÉTIQUETTE

Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifi ce size
Altitude

Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifi ce size
Altitude

5" WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
36,000 Btu/h (10.55 Kw/h)
18,000 Btu/h (5.28 Kw/h)
#33 DMS (2.87mm)
0-4500 ft/pi (0-1372m)

Pression d'allimentation minimum
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
Dimensions de l’orifi ce
L’altitude

Pression d'allimentation minimum
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
Dimensions de l’orifi ce
L’altitude

FACTORY EQUIPPED FOR NATURAL GAS

Model:H35-NG2

Convertible to 30,000
Orifi ce Size
Maximum Input
Minimum Input
Altitude

#37 DMS
30,000 Btu/h (8.78 Kw/h)
14,300 Btu/h (4.19 Kw/h)
0-4500 ft/pi (0-1372m)

Dimensions de l'orifi ce
Débit Calorifi que maximum selon
Débit Calorifi que minimum selon
L’altitude

Dimensions de l'orifi ce
Débit Calorifi que maximum selon
Débit Calorifi que minimum selon
L’altitude

FACTORY EQUIPPED FOR PROPANE GAS

Model:H35-LP2

12" WC/C.E. (3.00 kPa)
11" WC/C.E. (2.74 kPa)
2.9" WC/C.E. (0.72 kPa)
34,000 Btu/h (9.97 Kw/h)
17,500 Btu/h (5.13 Kw/h)
#51 DMS (1.70mm)
0-4500 ft/pi (0-1372m)

Convertible to 28,500 Btu
Orifi ce Size
Maximum Input
Minimum Input
Altitude

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas
and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCS-
BCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, Na-
tional Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24
CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCS-
BCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational

Vehicles.

Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifi ée est fournie.
This vented gas fi replace heater is not for use with air fi lters. Ne pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation.
For use with glass doors certifi ed with the appliance only Pour utilisation uniquement avec les portes en verre certifi ées avec l'appareil

Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.

NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE

FPI Fireplace Products International Ltd. Delta, BC, Canada Made in Canada/Fabrique au Canada 918-840

Minimum Clearances to Combustibles/Degagement
Minimum De Materiaux Combustibles
Minimum ceiling height from top of unit:36”/914mm
Minimum plafond hauteur en haut de l’appareil:

A 6-1/2”/165mm
B 6”/152mm

Minimum clearance of Vent Terminal to Outside Corner & Inside Corner:
with AstroCap 6"/150mm with Dura-Vent Cap 12"/300mm

C 2" / 50mm
E 2"/50mm

Serial No./ No de serie

E

E

A

A

Left Side Wall

Right Side Wall

Vertical

Pipe

A

A

B

C

Left Side Wall

Right Side Wall

Horizontal

Pipe

Model/Modele:

H35-NG2

Model/Modele:

H35-LP2

355

355

#52 DMS
28,500 Btu/h (8.35 Kw/h)
15,000 Btu/h (4.39 Kw/h)
0-4500 ft/pi (0-1372m)

ÉQUIPÉ A L'UISINE POUR GAZ NATURAL

ÉQUIPÉ A L'UISINE POUR GAZ PROPANE

DUPLICATE SERIAL NO.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.